INDIGO Home University of Illinois at Urbana-Champaign logo uic building uic pavilion uic student center

A dynamic noise level algorithm for spectral screening of peptide MS/MS spectra

Show full item record

Bookmark or cite this item: http://hdl.handle.net/10027/7746

Files in this item

File Description Format
PDF 1471-2105-11-436.pdf (1MB) (no description provided) PDF
Title: A dynamic noise level algorithm for spectral screening of peptide MS/MS spectra
Author(s): Xu, Hua; Freitas, Michael A.
Subject(s): proteomics tandem mass spectra
Abstract: Background: High-throughput shotgun proteomics data contain a significant number of spectra from non-peptide ions or spectra of too poor quality to obtain highly confident peptide identifications. These spectra cannot be identified with any positive peptide matches in some database search programs or are identified with false positives in others. Removing these spectra can improve the database search results and lower computational expense. Results: A new algorithm has been developed to filter tandem mass spectra of poor quality from shotgun proteomic experiments. The algorithm determines the noise level dynamically and independently for each spectrum in a tandem mass spectrometric data set. Spectra are filtered based on a minimum number of required signal peaks with a signal-to-noise ratio of 2. The algorithm was tested with 23 sample data sets containing 62,117 total spectra. Conclusions: The spectral screening removed 89.0% of the tandem mass spectra that did not yield a peptide match when searched with the MassMatrix database search software. Only 6.0% of tandem mass spectra that yielded peptide matches considered to be true positive matches were lost after spectral screening. The algorithm was found to be very effective at removal of unidentified spectra in other database search programs including Mascot, OMSSA, and X!Tandem (75.93%-91.00%) with a small loss (3.59%-9.40%) of true positive matches.
Issue Date: 2010-08-23
Publisher: BioMed Central
Citation Info: Xu, H. & Freitas, M. A. 2010. A dynamic noise level algorithm for spectral screening of peptide MS/MS spectra. BMC Bioinformatics, 11: 436. DOI: 10.1186/1471-2105-11-436
Type: Article
Description: © 2010 Xu and Michael; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The original work is available through BioMed Central at DOI: 10.1186/1471-2105-11-436
URI: http://hdl.handle.net/10027/7746
ISSN: 1471-2105
Sponsor: The study was funded by The Ohio State University, the National Institutes of Health (CA107106, CA101956), the V Foundation (AACR Translational Cancer Research Grant), the Leukemia & Lymphoma Society, (SCOR), the University of Illinois at Chicago, and the Searle Funds at the Chicago Community Trust to the Chicago Biomedical Consortium.
Date Available in INDIGO: 2011-05-27
 

This item appears in the following Collection(s)

Show full item record

Statistics

Country Code Views
United States of America 147
China 38
United Kingdom 17
Netherlands 3
Russian Federation 3

Browse

My Account

Information

Access Key