INDIGO Home University of Illinois at Urbana-Champaign logo uic building uic pavilion uic student center

Biomechanical validation of upper extremity exercise in wheelchair users: design considerations and improvements in a prototype device

Show simple item record

Bookmark or cite this item: http://hdl.handle.net/10027/8492

Files in this item

File Description Format
PDF Wheelchair_exercise_Troy_accepted _2_.pdf (370KB) (no description provided) PDF
Title: Biomechanical validation of upper extremity exercise in wheelchair users: design considerations and improvements in a prototype device
Author(s): Troy, Karen L.
Abstract: Purpose: To develop guidelines for proper exercise execution on a novel device and to recommend design changes to the device based on biomechanical data and user feedback. Method: Seven manual wheelchair users were instructed on proper exercise technique with a novel device, which allows a person to complete a seated row. Kinematics and kinetics of the dominant upper limb and trunk were measured with motion capture and electromyography data were collected on select muscles. Results: All subjects were able to exercise on the device with a mean power of 21.3 W (SD 7.1 W). Subjects did not keep the elbows close to the trunk during the drive phase of the row; rather, they moved from mean 75° (SD 12°) shoulder flexion to mean 62° (SD 11°) shoulder abduction. Identified problems included difficulty gripping the hand grips and user stability within the wheelchair. Conclusions: The accessory unit should be adjustable to accommodate a wide range of user sizes and abilities. Proper exercise execution is important to maximize the potential benefit and minimize risk of injury. When executed properly, this exercise may benefit wheelchair users by improving cardiovascular fitness and strengthening muscle groups linked to the reduction of shoulder pain.
Issue Date: 2011-01
Publisher: Informa Healthcare
Citation Info: Troy, K. L. 2011. Biomechanical validation of upper extremity exercise in wheelchair users: design considerations and improvements in a prototype device. Disability and Rehabilitation: Assistive Technology , 6(1): 22-28. doi:10.3109/17483107.2010.509883
Type: Article
Description: © 2011 by Informa Healthcare, Disability and Rehabilitation: Assistive Technology. doi:10.3109/17483107.2010.509883
URI: http://hdl.handle.net/10027/8492
ISSN: 1748-3107
Sponsor: Funding for this research was provided by NIDRR grant H133E070029.
Date Available in INDIGO: 2012-08-16
 