1303.pdf (762.37 kB)
Download fileA Clove-Hitch Suture Method for Small-Caliber Tendon Ends
journal contribution
posted on 2013-11-22, 00:00 authored by Edward Abraham, Alan League, Farid Amirouche, Nikhil KulkarniBackground: The choices of suture methods used to secure the end of a small-caliber tendon with a combination
of suture materials passing through and looping around the tendon are not well documented. A secure stitchtendon
unit may be an important factor in preserving muscle function, by facilitating healing without gapping or
failure.
Methods: Five types of suture methods utilizing four or fewer passes through the tendon end were mechanically tested
on 178 canine flexor digitorum profundus tendons. An Instron apparatus was used to test the load to failure.
Results: The single and double clove-hitch suture methods demonstrated improved repair strength when compared with
the three other methods studied in this small-caliber canine tendon model.
Conclusions: The single and double clove-hitch suture method better secured the end of a small-caliber tendon compared
with other methods.
Clinical Relevance: The single (pull-out) and double (non-pull-out) clove-hitch suture methods are reliable alternatives
for the repair of small-caliber tendons.
History
Publisher Statement
This is a copy of an article published in the Journal of Bone and Joint Surgery, American Volume © 2012 Journal of Bone and Joint Surgery, IncPublisher
Journal of Bone and Joint Surgery, IncLanguage
- en_US