posted on 2021-03-04, 00:46authored bySanjeeta Ghimire, Joseph Schulenberg
Dam operators often do not know whether an auxiliary spillway will fail until it is loaded,which can be infrequent. Such failures have the potential to result in overall dam failure leading to loss oflife and substantial property damage. The purpose of this paper is to develop a screening technique toidentify potentially risky auxiliary spillways. The paper uses the National Inventory of Dams (NID) dataand analyzes a sample of 400 earthen dams with auxiliary spillways. The main innovation of the paper isto employ code to create multiple input files and analyze them in the Windows Dam Analysis Modules(WinDAM) C software. This technique is more efficient than the current functionality of WinDAM C thatevaluates one dam at a time. The proposed method serves as a quick screening and decision-making toolfor multiple embankments for extreme flooding events by identifying potentially risky auxiliary spillwaysthat may require in-depth analysis. The results of this screening found 75% of spillways are likely tosustain heavy damage. Additionally, heavy damage was related to narrower spillway widths.
History
Publisher Statement
This material may be downloaded for personal use only. Any other use requires prior permission of the American Society of Civil Engineers. This material may be found at https://doi.org/10.1061/(ASCE)HY.143-7900.0001889
Citation
Ghimire, S.Schulenberg, J. (n.d.). An Automated Screening Technique to Identify At-Risk Auxiliary Spillways: Modified Approach in WinDAM. Journal of Hydraulic Engineering. https://doi.org/10.1061/(ASCE)HY.143-7900.0001889